SD780
1. Mini design with PIM integrative module(Voltage 380V) and IPM Intelligent Power Module(Voltage 220V)
2. Output 200% rated torque when frequency 1.5Hz
3. Flexible PWM Technology, electromagnetic noise of motor and electromagnetic radiation can be reduced to 70%,if compare with traditional PWM Technology
4. Intelligent regulator technology can fast control voltage and current of generatrix when accelerate, constant velocity and decelerate,can Implement excellent accelerate and decelerate characteristics,at the same time inverter can avoid useless trip.
5. New automatic Torque boost technology,use simple flux control,can Implement excellent Torque control better than common V/F control
6. Automatic current limiting function,automatic limit current in run-time, avoid frequently over current trip
Naming Rule
Name Plate
Model and Technichal Parameters
Voltage | Inverter Model | Rated capacity (kVA) | Output C(A) | Adaptable motor (KW) |
220V | XXX-2S0007 | 1.4 | 4 | 0.75 |
XXX-2S0015 | 2.6 | 7 | 1.5 | |
XXX-2S0022 | 3.8 | 10 | 2.2 |
Item |
Specifications |
|
Input |
Rated Voltage/Frequency |
Single Phase:220V,Three Phase:220V;50Hz/60Hz |
Allowable Variablerange |
Voltage:-20%~+20% ,Voltage imbalance rate:<3% ,Frequency:±5% |
|
Output |
Rated Voltage |
0~220V |
Voltage Range |
0Hz~400Hz |
|
FrequencyResolution |
0.01Hz |
|
Overload capacity |
150% Rated Current:1 minute,180%:1 second ,200%:Instantaneous protection |
|
Basic Functions |
modulation mode |
Optimization Space Voltage Vector PWMmodulation |
FrequencyAccuracy |
Digital Setting:Maximum Frequency ×±0. 01%; |
|
FrequencyResolution |
Digital Setting:0.01Hz;Analog Setting:Maximum Frequency ×0.1% |
|
Start upFrequency |
0.40Hz~10.00Hz |
|
Torque boost |
AutomaticTorque boost |
|
V/F Curve |
Linear V/F Curve,Square V/F Curve,Customized V/F Curve |
|
Acceleration and deceleration Time |
Optional Hourly basis(Min/Sec) ,The longest:3600(0.1-3600) |
|
AC Braking |
Optional during starting and halting::Operation frequency:0~20.00Hz |
|
Inching |
Inching frequency range:0.1Hz~50.00Hz, |
|
Built in PID |
Composition closed-loop control system easily for controlling pressure and flux progress |
|
Multistage speed running |
Realizing multistage speed via built in PLC or control terminal |
|
Textile swing frequency |
Swing frequency Function can realize set or regulate range of oscillation |
|
Automatic Voltage Regulation(AVR) |
Output constant voltage when voltage change in grid |
|
Automatic Energy-saving running |
Automatic optimize V/F Curve base on load and realize Energy-saving running |
|
Automatic limit Current |
Automatic limit Current during running ,avoid frequently overload trip |
|
Communication |
RS485 Standard Interface,supporting two formats MODBUS protocol :ASCII and RTU With Master-Slave linkage function. |
|
Operation Functions |
Running command channel |
Operation Interface setting,Control terminal setting, Serial port setting.Can change three modes. |
Frequency Setting Channel |
Keypad analog Potentiometer setting;Keypad▲,▼ setting;Function code digital setting;Serial port setting;Terminal UP/DOWN Setting;Analog Voltage setting;Analog current setting,Pulse setting;Combination setting;Can change multiple modes |
|
Switch Input channel |
Positive inversion instruction;5 channels programmable switch input,can set 35 functions individually. |
|
Analog Input channel |
2 channels analog signal input,4~20mA、0~10V optional |
|
Analog Output channel |
Analog signal output, 4~20mA or 0~10Voptional,can set frequency and output frequency |
|
Operation Interface |
LED Digital display |
Display set frequency,output voltage,output current,etc parameters |
External meter display |
Output frequency,output current,output voltage etc |
|
Protection |
Over Current protection;Over Voltage protection;Under Voltage protection; Over heat protection;Overload protection |
|
Optional accessories |
Braking combination;Remote operation interface;Remote electric cable; |
|
|
Installation location |
Indoor, ,free from direct sunlight, dust, corrosive gas,Oiliness gas, water vapour |
Altitude |
Less than 1000m(More than 1000m need derating) |
|
temperature |
-10℃~+40℃ |
|
Ambient temperature |
Less than 90%RH,no water condenses |
|
Vibration |
Less than 5.9m/sec 2(0.6G) |
|
Storage temperature |
-20℃~+60℃ |
|
Structure |
Level of Protection |
IP20 |
Cooling-down method |
Forced air cooling |
|
Installation |
Wall-mount |
Applications:
Paper-Making Industry
Elevator,Hoisting Equipment
Printing and Packaging Industry
Metallurgical Industry
Metalworking Indystry
Mediacal pharmaceutical and Food processing Industry